[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[sc-users] [linux] Impulse question



Hi All,

I found something strange which is at least to me quite counterintuitive 
and feels wrong:

	{ Impulse.ar(1) }.play

does not output the first impulse properly (or at all). Is this 
intendet behaviour? Can others replicate that? I would expect the 
behaviour to be that the first samples output by the ugen is the impulse 
so that:

	{ Impulse.ar(0) }.play

would output exactly one impulse and never progress any further. Am I 
wrong in my assumptions or is this a possible bug? I think at least that 
even when supplying a very low value like 0.00001 to the freq argument 
it should definitely output the first impulse no matter what, no?

I use 3.3 on Debian/Lenny.

Thanks to all,

karsten

-- 
-- http://krgn.goto10.org

Attachment: signature.asc