Hi All,
I found something strange which is at least to me quite counterintuitive
and feels wrong:
{ Impulse.ar(1) }.play
does not output the first impulse properly (or at all). Is this
intendet behaviour? Can others replicate that? I would expect the
behaviour to be that the first samples output by the ugen is the impulse
so that:
{ Impulse.ar(0) }.play
would output exactly one impulse and never progress any further. Am I
wrong in my assumptions or is this a possible bug? I think at least that
even when supplying a very low value like 0.00001 to the freq argument
it should definitely output the first impulse no matter what, no?
I use 3.3 on Debian/Lenny.
Thanks to all,
karsten
--